DCM
 
 
Tel: +86-571-86625003
Email1: info@optictrans.com
Email2: kally@optictrans.com
WhatsApp: +86 13967163428
Skype: hightech086
 
 
Keyword:
 
  Products
OP-DWDM-TAWG Thermal AWG DWDM Module
   Content
The specifications serve for C-band 80 channels Flat-top MUX/DEMUX Athermal AWG module in DWDM system.
 
Optical Specifications
Parameters
Specifications
Units
Notes
Min
Max
Channels
80
Ch
 
Channel Spacing
50
GHz
 
Reference Pass-band
± 0.05
nm
Relative to ITU Grid
ITU Frequency
192.1
196.05
THz
C-band
ITU Wavelength
1529.163
1560.606
nm
C-band
Center Wavelength Accuracy
 
± 0.024
nm
Maximum of the absolute deviation of the 3 dB center wavelength from ITU grid over all channels
0.5 dB Bandwidth
0.1
 
nm
0.5 dB from min Insertion Loss, full width, worst case polarization
1dB Bandwidth
0.2
 
nm
1dB from min Insertion Loss, full width, worst case polarization
3dB Bandwidth
0.3
 
nm
3 dB from min Insertion Loss, full width, worst case polarization
20 dB bandwidth
 
0.6
nm
20 dB from min Insertion Loss, full width, worst case polarization
Insertion Loss
 
7
dB
Maximum of the insertion loss across the ITU pass-band over all channels
Ripple
 
0.5
dB
Maximum of the loss variance across the ITU pass-band over all channels
Insertion Loss Uniformity
 
1.5
dB
Maximum insertion loss variance across all channels
Adjacent Channel Isolation
25
 
dB
Ratio of peak transmission to the maximum transmission over both adjacent pass-bands
Non-Adjacent Channel Isolation
30
 
dB
Ratio of peak transmission in channel pass- bands to maximum transmission over all non- adjacent pass-bands
Total Crosstalk
20
 
dB
Ratio of power in channel to power in all other pass-bands
Polarization Dependent Loss
 
0.5
dB
Maximum ratio of transmissions over all polarization states, over the ITU pass-band
Return Loss
40
 
dB
 
Polarization Mode Delay (PMD)
 
0.5
ps
In Reference Pass band over all channels
Chromatic Dispersion
-20
20
ps/nm
In Reference Pass band over all channels
 
Electrical Specifications
Electrical and Temperature Control Specifications
Parameters
Specifications
Units
Notes
Min
Typ
Max
Set-Point temperature of component
65
 
85
°C
Operating temperature. The commands could only set current temperature and threshold in this range.
Set-Point temperature stability
 
 
±0.2
°C
Over entire operating temperature range for thermal AWG
Heater Driving Voltage
 
+5
 
V
 
Heater Driving Current
 
 
2.5
A
 
Heater Power Dissipation
 
 
12.5
W
 
AWG Temperature Settling Time
 
 
15
min
AWG warm up time from a cold start (-15°C ambient temperature) to the set-point temperature.
 
Environmental Conditions
Parameters
Specifications
Units
Min
Typ
Max
Operating Temperature
-5
 
65
°C
Storage Temperature
-40
 
85
°C
Relative Humidity
0
 
90
%
All parameters are the worst-case across clear ITU window, over all temperature range (-5°C to 65°C) and all States of polarization. Connector loss is included.
 